Replacement Power Head for Taco Zone Sentry Valve, Normally Open

Replacement Power Head for Taco Zone Sentry Valve, Normally Open
Replacement Power Head for Taco Zone Sentry Valve, Normally Open QR Code
QR-Code
Views: 4799 Model: ZB024Q4A1
UPC: 687752882407

MPN: ZB024Q4A1

Availability:1

Weight:0.50 lb

Dimensions (L x W x H ): 6.00 x 2.50 x 2.50

Usually ships: 1 business days
$110.95
Qty: Add to Cart

ORDERS OVER $99 SHIP FREE

Have any questions?
Contact us at 1-800-246-9552

The ZB024Q4A1 from Taco is a Replacement Power Head for Taco Zone Sentry Zone Valves, Normally Open. It provides on-off control in both open and closed hot or chilled water hydronic systems.

The state of-the-art features of Actuator Head make the control truly universal and will prove to be both reliable and efficient. It is loaded with innovative technology and boasts a new Prostar Capacitor and a reliable high-torque, high-efficiency miniature motor. The quick Snap-in connects on the back of the valve ensuring a simple, secure and fast wiring hook-up. A green LED light shows full functionality of the valve.


Features:

  • Taco ZB024Q4A1 Zone Sentry;
  • Replacement Actuator Head;
  • Normally Open Position;
  • Uses up to 93% less energy than other commonly installed zone valves;
  • Multi function LED assists with troubleshooting;
  • The actuator mounts on the valve in either direction;
  • Replaces Taco EN024Q4A2 and AN024Q4A2 Actuator Heads.


Technical Specifications:

  • Maximum Operating Pressure: 300 psi;
  • Maximum Shutoff Pressure: 125 psi;
  • Fluid Temperature Range: 20 to 240°F (-7° to 115°C) @ 135°F (57°C) ambient;
  • Service: Closed systems, Optional open system configuration, Up to 50% Glycol;
  • Ball Rotation Speed: Full Open to Full Close / Full Close to Full Open (90° turn), 5 seconds (after charge time);
  • Seat Leakage: Drop-Tight Close-Off;
  • Electrical Rating: 24 VAC, 60 HZ, 0.48 Amps;
  • Do not exceed number of valves per transformer rating;
  • Example: Do not use more than 12 zone valves per 40VA transformer;
  • Power Consumption, Charging: 11.4 Watts, 0.48 Amps;
  • Power Consumption, Power On: 1.44 Watts, 0.06 Amps;
  • Heat Anticipator Setting: 0.5 Amps;
  • End Switch Rating: 1 Amp at 24 VAC.
Product Specs
Electrical Rating:24 VAC, 60 HZ, 0.48 Amps
End Switch Rating:1 Amp at 24 VAC.
Heat Anticipator Setting:0.5 Amps
Maximum Operating Pressure:300 psi
Maximum Shutoff Pressure:125 psi
Power Consumption, Charging:11.4 Watts, 0.48 Amps
Power Consumption, Power On:1.44 Watts, 0.06 Amps
Seat Leakage:Drop-Tight Close-Off