G115WS/4 Logano Oil-Fired Boiler, 95,000 BTU
Click Image for Gallery
          
                              
                                        
                    
          Buderus G115WS/4 Logano-series model is Energy Star listed, floor-standing, 4-section, residential oil-fired boiler with 87% AFUE and 95,000 BTU (Net) rating.
Includes B-Kit comprised of burner mounting bolts set, supply manifold (1-1/4" x 1-1/4" x 3/4" x 1/4"), 1-1/4" black 90° elbow, 3/4" black 90° elbow, 1-1/4" x 3" black pipe nipple (BST x NPT), boiler drain, 30 psi relief valve, T&P gauge and adjustable boiler feet.
Note: burner kit sold separately.
For use with part# 7738004842 chimney vent KP kit (includes Riello F5 oil burner, Grundfos circulator w/ IFC, Hydrolevel Hydrostat 3250 control, 3ft flexible oil line and wiring harness). For direct vent, use part# 7738004851 KP kit (incl. Riello BF3 burner, Grundfos circulator, 3250 control, 3ft oil line and wiring harness).
Note: if you are buying this boiler in conjunction with LT Series indirect water heater, make a note in the checkout and we will include mounting hardware free of charge.
Includes B-Kit comprised of burner mounting bolts set, supply manifold (1-1/4" x 1-1/4" x 3/4" x 1/4"), 1-1/4" black 90° elbow, 3/4" black 90° elbow, 1-1/4" x 3" black pipe nipple (BST x NPT), boiler drain, 30 psi relief valve, T&P gauge and adjustable boiler feet.
Note: burner kit sold separately.
For use with part# 7738004842 chimney vent KP kit (includes Riello F5 oil burner, Grundfos circulator w/ IFC, Hydrolevel Hydrostat 3250 control, 3ft flexible oil line and wiring harness). For direct vent, use part# 7738004851 KP kit (incl. Riello BF3 burner, Grundfos circulator, 3250 control, 3ft oil line and wiring harness).
Note: if you are buying this boiler in conjunction with LT Series indirect water heater, make a note in the checkout and we will include mounting hardware free of charge.
Technical Specifications:
- Gross Output (BTU): 109,000 - chimney vent
 - 98,000 - direct vent
 - Net IBR Rating (BTU): 95,000 - chimney vent
 - 85,000 - direct vent
 - Oil Firing Rate (GPH): 0.9 (chimney vent)
 - 0.8 (direct vent)
 - Efficiency (AFUE): 87%
 - Boiler Type: Non-Condensing (cast-iron heat exchanger)
 - Number of Sections: 4
 - Fuel Type: #2 Oil
 - System Type: Hydronic (Hot Water)
 - Boiler Connections: 1-1/4" NPT Supply, 1" NPT Return
 - Max. Working Pressure: 58 psi
 - Max. Output Water Temperature: 194°F
 - Vent Size: 5"
 - Vent Material: Regular Chimney Pipe or Flexible Stainless Steel (see Literature for tips & details)
 - Insulation thickness: 3"
 - Mounting Type: Floor-standing
 - Dimensions (Depth x Width x Height): 23-5/8" x 28-5/8" x 34-1/2"
 - Recommended Clearance: 15" side, 20" rear
 - Weight (lbs): 403
 - Water Volume (gallons): 10.8.
 
| Product Specs | |
| Net BTU Rating | 75,000 - 100,000 | 
| Product Type | Boilers | 



















































































































































































































                        
                        